Thickness Of Rcc Roof

Minimum Thickness Of Slabs Without Interior Beams Slab Diy Foundation Stress

Minimum Thickness Of Slabs Without Interior Beams Slab Diy Foundation Stress

Standard Room Height Lintel Thickness Footing Size In A Building How To Level Ground Civil Engineering Construction Grade Of Concrete

Standard Room Height Lintel Thickness Footing Size In A Building How To Level Ground Civil Engineering Construction Grade Of Concrete

Reinforcement Detailing Of Rcc Slabs Concrete Slab Civil Engineering Reinforcement

Reinforcement Detailing Of Rcc Slabs Concrete Slab Civil Engineering Reinforcement

Inclined Pitched Roof Concrete Slab Reinforcement Example Concrete Slab Pitched Roof Concrete

Inclined Pitched Roof Concrete Slab Reinforcement Example Concrete Slab Pitched Roof Concrete

Slab Hidden Beam Reinforcement Cross Section Detail Beams Slab Structural Engineering

Slab Hidden Beam Reinforcement Cross Section Detail Beams Slab Structural Engineering

Reinforced Concrete Sloped Roof Slab Overhang Detail Cantilever Overhang Inclined Slab Supported From A Reinforced Concrete Be Roof Edge Concrete Roof Concrete

Reinforced Concrete Sloped Roof Slab Overhang Detail Cantilever Overhang Inclined Slab Supported From A Reinforced Concrete Be Roof Edge Concrete Roof Concrete

Reinforced Concrete Sloped Roof Slab Overhang Detail Cantilever Overhang Inclined Slab Supported From A Reinforced Concrete Be Roof Edge Concrete Roof Concrete

2 bars of 12 mm in the bottom and 2 bars of 10 mm on the top.

Thickness of rcc roof.

In this article i have described step by step rcc roof slab steel calculation. Rcc roof slab reinforcement details the cross sectional dimension for the column can be 9 x9 or 9 x12 with minimum 4 steel bars of 12 mm with stirrups of. Reinforced concrete slabs are heavier and generate higher seismic forces in an event. So read it carefully one by one to get a clear understanding.

Such slabs left unconnected to walls caused many deaths in the 2005 quake from school roof collapses. Slab a one way slab. The thickness has to be at least 4 5 5 0. With out slab one can not take benefit of any structure like building culvert bridge.

4 bars of 12mm steel rods fe 500 2. For beam it should be 16mm and 12 mm as per span. 6 of pcc layer comes first. Use 10 12 mm for lantel area and 16 mm for invisible beams.

Slab is a structural member which enable people to move from one floor and one place to another place in a flat. Ms steel for slab for main bar should be 10mm and for distribution 8mm or 10 mm. Ideal beam size should not be less than 9 x9 with a minimum of4 steel bars with 2 bars of 12 mm thickness in the. 1 2 minimum thickness of ribbed slab aci 318 14 recommend the same value of non prestressed beams as provided in table 2.

Over than a. Main steel 8 mm bars 6 c c and distribution steel of 6 mm bars 6 c c b two way slab. Unified building code ubc specified minimum thickness of ribbed slab to be 1 12 distance between ribs or 51mm. If reinforced concrete were to be reused strong connections would have to be made between roof and walls.

Reinforced Concrete Pitched Roof Apex Slab Reinforcement Detail Reinforced Concrete Pitched Roof Roof Construction

Reinforced Concrete Pitched Roof Apex Slab Reinforcement Detail Reinforced Concrete Pitched Roof Roof Construction

Slab Hidden Beam Reinforcement Cross Section Detail Beams Reinforced Concrete Concrete

Slab Hidden Beam Reinforcement Cross Section Detail Beams Reinforced Concrete Concrete

How To Determine The Quantity Of Any Sloping Roof Roof Construction Concrete Mix Design Roof

How To Determine The Quantity Of Any Sloping Roof Roof Construction Concrete Mix Design Roof

Reinforced Concrete Retrofit Bundled Set Of Details Concrete Column Reinforced Concrete Concrete Floors

Reinforced Concrete Retrofit Bundled Set Of Details Concrete Column Reinforced Concrete Concrete Floors

Source : pinterest.com